3 Questions
Does the 2.2kW 3 phase model have connection for brake resistor and external potentiometer and controls?
This inverter can be connected to a brake resistor, which is connected to the DC+ and DB terminals. The parameters of the brake resistor are 300W, 250Ω. An external potentiometer can be used to control the frequency of the inverter. The resistance of the potentiometer is 4.7K, which is connected to the AI1, GND and P12 terminals, and the parameter F002 is set to 1.
By vevor
La ce turație ajunge motorul
Turația motorului poate fi găsită pe plăcuța de identificare a motorului. Convertorul de frecvență poate fi setat în funcție de frecvența nominală și de turația nominală a motorului.
By vevor
My motor hase an bimetal switch (NC) for protection. How do I wire It to the VFD, so the VFD Powers down in case of Motor overheating
Connect the motor's NC bimetal switch to a programmable digital input on the VFD configured as an external fault/stop input. When the motor overheats, the switch opens, causing the VFD to stop the motor and enter a fault state.