15 Questions
Hello, I have a single phase motor already, can I just connect one single phase? Or is it necessary to connect always all the phases and use a three phase motor? Thank you
This inverter can be connected to single-phase motor and connected to U and W terminals. And ensure that the motor power is less than 3Kw, because the current of single-phase motor will be very high.
By vevor
Can this inverter/vfd be connected to you 2hk 8x82 belt grinder wich has a 2hk/1,5kw single phase motor? https://eur.vevor.com/belt-grinder-c_11006/belt-grinder-2-x-82-complete-chassis-3-tool-rest-w-2hp-motor-3-in-1-sander-p_010288052332
It is not recommended to drive a single-phase motor. The starting current of a single-phase motor is 4-5 times the rated current.
By vevor
Can this control https://eur.vevor.com/spindle-motor-c_10130/vevor-square-air-cooled-spindle-motor-2-2kw-cnc-spindle-motor-220v-er20-collet-p_010648959518
It can drive the spindle motor. You need to set F005 to 400, F004 to 400, F003 to 400, and F144 to 24.00.
By vevor
Can this control https://eur.vevor.com/spindle-motor-c_10130/vevor-square-air-cooled-spindle-motor-2-2kw-cnc-spindle-motor-220v-er20-collet-p_010648959518, but not manually but by software via 10 V in terminal? Many thanks, Marko
The 0-10 analog signal can be used to control the frequency of the inverter to control the speed of the motor. The 0-10V analog signal is connected to the GND and AI1 terminals, and the parameter F002 is set to 1 (AI1).
By vevor
Yes, you can control the spindle running, stopping and speed through the inverter control keyboard. The green RUN key on the inverter control keyboard can control the spindle running, the red STOP key can control the spindle stopping, and the white knob can control the spindle speed. Before driving the spindle, you need to set the spindle frequency and speed in the inverter parameters, F005 is set to 400, F004 is set to 400, F003 is set to 400, and F144 is set to 24.00.
By vevor
Good Evening I received my 2 inverters this evening to find they are only 220v 3 phase output I need 380v output
This inverter can only output 220V, not 380V.
By vevor