VEVOR EU EN
Select the country/region, language, and currency you prefer for shopping.
Delivery to
Your Address
Hello, Sign In
Account & Order
Categories
Download VEVOR App
Exclusive 5,00€ off on your first three app orders. Only App.
Scan the QR code to download
VEVOR refrigerant recovery tank with dual valves, brass fittings, and durable design. VEVOR refrigerant recovery tank with nitrogen, 50 lbs, connected to equipment near a car bumper. VEVOR refrigerant recovery tank with sae to acme adapters, compatible with various refrigerants. VEVOR refrigerant recovery tank with explosion-proof pressure relief valve, high pressure resistance. VEVOR gas cylinder made from thick hp295 steel with powder coating. rust resistant. VEVOR refrigerant recovery tank featuring brass y-valve, vapor and liquid valves, and 1/4" sae fitting. VEVOR refrigerant recovery tank with brass adapters, dimensions 18.1" x 11", 50 lb capacity.
LMHSGWFDK501495VYV0

VEVOR Refrigerant Recovery Reclaim 50lb Cylinder Tank 400 PSI liquid Rated Y Valve

Price including VATSee details
Save up to 15% with PRO price. Sign up for free PRO Account.
Exclusive 5,00€ off on your first three app orders. Only App.
Download Now
Exclusive 5,00€ off on your first three app orders. Only App.
Scan the QR code to download

About this item

  • Withstand High Pressure: Discover the unparalleled durability of the VEVOR refrigerant recovery tank! Pre-filled with a trace amount of nitrogen to guard against corrosion, it has undergone rigorous pressure tests and boasts a working pressure of a formidable 400 psi. Enjoy peace of mind with this tank's ability to resist high pressure, ensuring a safe and secure refrigerant recovery experience.
  • Strong Compatibility: The built-in 1/4" SAE interface valve can be adapted to fit most hose sizes, thanks to the inclusion of 2 1/4" SAE to 1/2" ACME brass adapters. Perfect for use with old household air conditioners, the tight connection at the interface minimizes the risk of leakage.
  • Explosion-proof & Non-leakage: Featuring an integral forming brass Y-valve with strong sealing capabilities, it can efficiently recover and discharge both liquid and steam. And, with the included pressure relief valve, you never have to worry about high pressure. If the tank's working pressure is exceeded, the valve will automatically relieve pressure for a safer user experience.
  • Cover Your Needs: With a 50 lb capacity, it's perfect for household vehicles. And, it's designed to handle a wide range of refrigerants including R134A, R-22, R-12, R410A, R404A, R502, R1234YF, and R32. Get the versatility you need.
  • Reusable Recover Tank: The tank body is crafted from durable HP295 steel with a sturdy 0.1-inch wall thickness. Its sleek high gloss powder coating and reinforced steel seal make it resistant to wear, even after extended use.

Frequently Bought Together

People Who Bought This Item Also Bought

VEVOR Refrigerant Recovery Reclaim 50lb Cylinder Tank 400 PSI liquid Rated Y Valve
Heavy-duty Refrigerant Recovery Tank
VEVOR refrigerant recovery tank and recovery machine with gauge, hoses connected, high pressure resistance.VEVOR refrigerant recovery tank and recovery machine with gauge, hoses connected, high pressure resistance.
VEVOR 50 lb refrigerant recovery tank with a trace amount of nitrogen is often used to recover refrigerant for household cars, refrigerators, air conditioners, etc.
  • VEVOR refrigerant recovery tank highlighted against alternatives, pre-filled with nitrogen to prevent corrosion.
  • VEVOR refrigerant recovery tank with brass y-valve, relief valve, 1/4"sae adapters, and interface valve.
  • VEVOR refrigerant recovery tank highlighted against alternatives, pre-filled with nitrogen to prevent corrosion.
  • VEVOR refrigerant recovery tank with brass y-valve, relief valve, 1/4"sae adapters, and interface valve.
  • VEVOR refrigerant recovery tank setup with gauges, ac unit, and hoses on a gray background.
  • VEVOR refrigerant recovery tank setup with gauges, ac unit, and hoses on a gray background.
Key Features
VEVOR refrigerant recovery tank, corrosion-proof with nitrogen pre-fill, compared to air-filled tank.
Filled with Nitrogen
The protective gas with strong stability does not produce water molecules and oxygen, effectively preventing oxidation and corrosion inside the tank.
VEVOR refrigerant recovery tank with relief valve, 1/4" sae to 1/2" acme adapters, and interface valve.
All-around Protection
We control the quality strictly. Through multiple pressure tests, the rated working pressure reaches 400psi, and the test working pressure reaches 800psi.
VEVOR refrigerant recovery tank with high pressure resistance, w.p: 400psi, t.p: 800psi.
Wide Compatibility and Tight Sealing
1/4" SAE interface valve is equipped with two adapters that are compatible with most hoses. The Y-type valve is integrally formed and explosion-proof, and leakage resistant.
VEVOR refrigerant recovery tank 50 lbs, hp295 steel, 19.6 lb, and 18.1" height with brass adapters.VEVOR refrigerant recovery tank 50 lbs, hp295 steel, 19.6 lb, and 18.1" height with brass adapters.

Specification

Capacity
50 lbs
Working Pressure
400psi/2.7MPa
Test Pressure
800psi/5.5MPa
Service Life
5 Year
Material
HP295 Steel
Product Dimensions
Φ11×18.1 inch / Φ280×460 mm
Net Weight
19.6 lb/8.9 kg
Temperature Range
-10℃-50℃/-50℉ - 122℉