How do i set over current limit? What is Torque Compensation (Pn 13)?
The supercurrent setting does not need to be set, currently, this option is not allowed, and the setting is fixed. Torque compensation means that the running torque of the motor is not enough at low speeds, and this parameter can be used to compensate. If you are single-phase 220v, please connect to R and T, and S does not need to be connected when it is empty. If you are three-phase 220v, then connect to RST. The three wires of the motor are connected to U, V, and W.
By vevor
Dear, Is it possible to use 4KW Variable Frequency CNC Drive on a 2.2 kW spindle motor? Many thanks, Marko
It is possible to use 4KW Variable Frequency CNC Drive on a 2.2 kW spindle motor.
By vevor
Is it possible to use this unit to drive a single phase fan motor? There seems to be no Neutral terminal output? Do I have to set specific paramters to do it?
No, single-phase motors cannot be driven by this inverter, it can only drive three-phase asynchronous motors with a voltage level of 220 volts.
By vevor
How can I start from a run position remotely?
Customers can control the drive by connecting an external latching pushbutton. Connect the pushbutton’s terminals to the drive’s GND and X1 terminals, and set parameter F001 to 1. When the pushbutton remains closed, the drive runs; when the pushbutton is released, the drive stops. If this answer does not resolve your issue, please contact us again for assistance.
By vevor
Hi, may I use RS485 protocol to control the driver?
No, it can only be controlled via external terminals.