Delivery to
goods.your_address
VEVOR EU EN/ EUR
Select the country/region, language, and currency you prefer for shopping.
Hello, Sign in
Account & Order
Categories
Download VEVOR App
Get 5,00€ Off 99,00€+ Orders on Your First 3 App Orders
Scan the QR code to download

Water Pressure Regulators

Price
Under 30
50 ~ 100
Customer Rating
5 stars only
4 stars and up
3 stars and up
2 stars and up
1 star and up
Special Offers
On Sale
Bulk Savings
In Stock
Pickup
Summer Sale
Quick look
New
VEVOR Hydrostatic Test Pump 7.57 L Hydraulic Manual Water Pressure Tester, Dual Valve Hydrostatic Water Pipe Leakage Pressure Test Pump Kit with Gauge & Tank, 0-60 Bar Range, for Pipeline, Heating
(29)
76.99
76.99
Deal after registering
Member discounted price
0% cash back at checkout.
76.99
Non-PRO Account
76.99
Save
Non-PRO Account
188 Views Recently
You May Also Like
Recently Viewed

Results for  Water Pressure Regulators

Before putting pipes and heating systems into service, plumbers, HVAC techs, and builders can use VEVOR hydrostatic test pumps to ensure they hold pressure. Choose from 1.6, 2, or 3-gallon manual units with one or two valves. Each includes a pressure gauge and a storage tank. The range, which goes from 0–30 bar to 0–60 bar, is wide enough to handle both simple home leak checks and tough commercial jobs. This range keeps projects on track and helps you catch leaks early.


VEVOR Hydrostatic Test Pumps for Reliable Pipeline and Heating Leak Testing 


Want to find a leak that keeps coming back? You don't have to guess when you use a VEVOR hydraulic test pump: pressurize a closed system and watch the gauge stay steady or drop. You can use these manual pumps to pull water from an onboard tank, build pressure, and find weak joints in plumbing, radiant heating, and irrigation lines before they break.


Tank Capacity and Valve Configuration Across VEVOR Hydrostatic Test Pumps 


What makes a unit work every day is how much water it can hold and whether it has one or two valves. Check out VEVOR's choices below.


Matching Tank Size to the Job 


The reservoir size determines how much water you can add before you have to refill it. VEVOR's hydraulic test pumps come in three tank sizes, so you can choose one that fits the work you do most often. For short home runs, single fixtures, and tight service calls where a smaller tank is easier to carry up a ladder or into a crawl space, the 1.6 gallon hydrostatic test pump is the best choice.


For a wider range of plumbing and heating jobs, the 2 gallon hydrostatic test pump is the next step up. Its larger volume means that it needs fewer top-ups over a longer hold. For big jobs, the 3-gallon hydraulic test pump keeps enough water on hand to fill larger pipe networks and maintain pressure for a longer test.


As a general rule, choose a tank that can fill your usual system in one pour. If you don't choose a large enough tank, you will have to make more trips to the water source, which slows down a quick check.


Dual Valve vs Single Valve 


Beyond size, the valve configuration affects how you build and release pressure. When you top off or bleed the line, a dual valve hydrostatic pressure pump gives you more control because the intake and pressure hold valves are different. VEVOR offers 1.6, 2, and 3-gallon tanks with dual valves, so you can match the control to the tank size you need.


For easier use and lower cost, a single valve hydrostatic test pump is best. It uses one valve for both intake and holding. You do not have to fine-tune the fill separately from the hold, so it is a good choice for simple leak checks.


It depends on how much pressure your jobs need. Neither way is better in and of itself. All VEVOR hydrostatic test pumps use the same tough pumping mechanism. This means the valve you choose affects performance, not lifespan.


Pressure Ranges That Match Capacity 


Each tank size has a rated pressure range. The 1.6-gallon unit can handle up to 30 bar, which is more than enough for light residential lines. The dual-valve 2 gallon can handle pressures from 0 to 60 bar, while the single-valve 2 gallon and 3 gallon models can handle pressures from 0 to 50 bar. This range covers most plumbing and heating jobs.


Why does this matter? To find hidden flaws, your test pressure usually needs to be much higher than the system's normal working pressure. This is why headroom is important. With VEVOR's hydrostatic test pumps, you can push a line above its working pressure and hold it long enough to catch a slow weep.


Reviews are very positive about the lineup; reviewers praise all four models. This shows the pressure performance works well in real life, not just on paper. It is always safer to choose a range with some room to spare than to buy right at the limit.


Picking the Right Combination 


Base capacity and valve type on the systems you test most. The compact 1.6 gallon dual-valve pump might work best for a service plumber who only needs to make quick calls to homes. When a worker has many different jobs to do, they usually choose a 2-gallon model. They can choose the dual-valve 2 gallon kit for better control or the single-valve 2 gallon kit to save some money. You can run longer tests without stopping with the 3 gallon dual-valve pump for commercial pipe networks. It has enough water and range.


With VEVOR's hydrostatic test pumps, every setup is affordable, so you can choose based on fit rather than price alone. Choose the valve setup that best fits your system and tank size. This will help the tester stay in your truck for years.


Real-World Applications and Gauge Features of Hydrostatic Test Pumps 


You should evaluate specs after you see them in action. This is where these testers really shine, and the gauge and tank make the job easy.


Where These Pumps Earn Their Keep 


The most common use is testing new or repaired plumbing for leaks before sealing it behind a wall. Once the line is full, pump until it reaches your target pressure. If the gauge stays steady, the joints are tight. It gives a clear pass-or-fail reading, so you don't have to guess.


You can use the same tool to cover radiant floor heating loops, boiler feed lines, irrigation runs, and fire sprinkler pipework. VEVOR markets the range as a pipeline and heating hydrostatic test kit, and for good reason: the top model's 0–60 bar ceiling is just right for the high pressures that closed systems need. You do not need an outlet on site for these hydraulic test pumps because they run completely by hand, whether they are small or big.


As a manual hydrostatic pressure tester, each VEVOR hydrostatic test pump gives trades a reliable way to test a system before it goes live. This reduces callbacks and keeps finished work safe from undetected leaks. Since it can hold pressure for a long time, the 0–50 bar 3 gallon tester is good for heavy industrial runs.


Reading the Gauge and Trusting the Tank 


The gauge is the most important part of the test. Every VEVOR model comes with a gauge and a tank, so you are always ready to go. As you load the system, watch the scale. If it stays steady, the system is holding pressure, but if it drops, you need to find and fix a leak.


Each unit comes as a complete hydraulic pressure test pump kit with the pump, gauge, reservoir, and connections you need to start testing right away. Because they come in one package, these hydrostatic test pumps work for both experienced professionals and first-time DIYers. For small jobs, the 0–30 bar 1.6 gallon unit is a good place to start.


To get the most accurate results, make sure there is no air in the line before you pressurize it. Trapped air can hide a slow leak. When you are done, slowly let the pressure drop. Used this way, VEVOR's hydrostatic test pumps deliver reliable, accurate readings test after test.


Why Choose VEVOR Hydrostatic Test Pumps? 


From small 1.6 gallon testers to full 3 gallon testers, VEVOR offers a line of affordable, well equipped pressure testers to meet your needs. You don't need to buy anything else because each kit includes the gauge, tank, and connections. That is true whether you choose the 0–60 bar dual-valve model for tough closed systems or the budget single-valve tester for quick leak checks. You will get professional results without the professional price. Get a VEVOR hydrostatic test pump today and test with confidence. 


FAQs


What size hydrostatic test pump should I choose?


Match the tank to your system volume. The 1.6 gallon unit suits small residential lines, the 2 gallon fits mixed plumbing and heating work, and the 3 gallon handles larger pipe networks that need a longer, uninterrupted pressure hold.


What's the difference between single and dual valve models?


A dual valve model uses separate valves for filling and holding pressure, giving finer control. A single valve model handles both through one valve, making it simpler and more affordable, and well suited to straightforward leak checks on smaller systems.


What can I test with these pumps?


They test plumbing lines, radiant heating loops, boiler feeds, irrigation, and sprinkler systems. Fill the closed line, pump to your target pressure, and a steady gauge confirms the system is leak-free before it goes into service.


Do these pumps need electricity?


No. Every VEVOR unit is a manual pump, so you build pressure by hand with no power source required. That makes them ideal for job sites and remote locations without an outlet.