Select the country/region, language, and currency you prefer for shopping.

Dissolved Oxygen Meters

Customer Rating
5 stars only
4 stars and up
3 stars and up
2 stars and up
1 star and up
In Stock
Pickup
Black Friday

We couldn't find a match

Please try with other options or clear your filters.

You May Also Like
Recently Viewed

Results for  Dissolved Oxygen Meters

A dissolved oxygen meter is an instrument that measures how much oxygen is dissolved in water and reports it as a concentration in milligrams per liter (mg/L) or as a percentage of saturation. A probe placed in the sample senses the oxygen passing across its membrane or optical window, and the meter converts that signal into a reading, usually shown next to the water temperature. Because the amount of oxygen in water sets whether living organisms and biological processes can survive in it, the device turns an otherwise invisible property into a number you can read, record, and compare over time.


VEVOR builds its dissolved oxygen meters in a few recognizable forms. Portable, handheld meters run on batteries and travel to the water, which suits river sampling, pond checks, and spot readings across an aquaculture site. Benchtop meters stay on a laboratory surface and favor fine resolution for analytical work. Across these forms the sensing is done either electrochemically, with a polarographic membrane probe, or optically, with a luminescent sensor that needs no membrane. Measurement ranges reach up to 50 mg/L with automatic temperature compensation and adjustable salinity and pressure correction, so one meter can read fresh, brackish, and saline water. Typical uses are aquaculture and aquarium monitoring, environmental and field sampling, and wastewater and aeration control.


Five things decide which meter you need:


  • Measurement range: match the meter's upper limit to your water, since high-oxygen surface water can exceed the range of a basic meter.
  • Accuracy and resolution: general aquaculture is fine around 0.5 mg/L, while trend tracking and compliance work want finer 0.01 mg/L resolution.
  • Temperature compensation: automatic correction (ATC) keeps readings honest as water temperature shifts during a sampling run.
  • Salinity and altitude correction: enable these for coastal, marine, or high-elevation sites, or the meter will misread.
  • Portability and data handling: decide between a field-ready handheld with on-board storage and a benchtop unit for controlled lab logging.

Browse the full range of VEVOR dissolved oxygen meters to match a meter to your water, or compare the portable tester kit for day-to-day field and pond monitoring.


Dissolved Oxygen Meter Types at a Glance


The table below sets the main meter types side by side so you can match a form and sensor to where you will actually use it.


Type Sensor / Method Maintenance Need Best Working Setting Selection Note
Portable electrochemical meter Polarographic membrane probe Membrane and electrolyte need periodic care Ponds, rivers, and aquaculture field checks Choose when you carry the meter to the water for hands-on sampling
Optical (luminescent) meter Luminescent optical sensor, no membrane Low upkeep, no membrane to replace Longer monitoring runs and low-maintenance use Pick for fewer consumables and steadier readings over time
Benchtop meter Polarographic or optical, bench mounted Controlled, scheduled calibration Laboratory and analytical work Best where fine resolution outweighs the need to move around

VEVOR Dissolved Oxygen Meters for Precise, Reliable Water Quality Monitoring


Want to get exact readings of dissolved oxygen in the lab, on the farm, in the field, or without having to invest in large, expensive equipment? With VEVOR's line of dissolved oxygen meters, you can get accurate measurements for any monitoring situation in a small, portable device. Every instrument in the range is designed to work consistently and reliably in demanding real-world conditions. This includes portable DO meters for field use by one person and high-resolution benchtop dissolved oxygen testers for controlled analytical work.


Measurement Range & Accuracy: How to Select a Dissolved Oxygen Meter


The two most important performance criteria for determining whether a dissolved oxygen meter is right for your application are its measurement range and accuracy. If your device doesn't have the correct measurement range, it will saturate at the upper limit in high-oxygen environments. Furthermore, if the readings aren't accurate, you can't trust them to make important decisions about water quality. It is important to fully understand both specifications before making a purchase.


Understanding Measurement Range: Matching DO Meter Specifications to Your Water Environment


The amount of dissolved oxygen in natural and managed water environments varies widely depending on temperature, salinity, elevation, biological activity, and the purpose of the monitoring. DO levels in freshwater aquaculture systems with the right number of fish usually fall between 6 and 12 mg/L, a middle range that most common dissolved oxygen meters can measure.


When measuring for environmental monitoring purposes, such as river sampling, lake stratification studies, and estuary assessment, the measurement range needs to be wider. This is because DO levels can range from almost zero in anoxic bottom sediments to supersaturation in surface layers during peak photosynthesis.


Accuracy Specifications: What Resolution and Repeatability Mean for Real-World Water Quality Decisions


To find out how accurate a dissolved oxygen tester is, look at its resolution (the smallest change it can detect and report) and measurement uncertainty (usually expressed as a plus-or-minus percentage of the reading or a set mg/L tolerance). Most entry-level DO meters say that their accuracy is within ±0.5 mg/L across their entire measurement range. This is fine for general aquaculture tracking and hobbyist aquarium management, where rough DO levels are sufficient for daily care decisions.


Resolution, on the other hand, is distinct from accuracy. A meter with 0.01 mg/L resolution can show finer changes in dissolved oxygen content than one with 0.1 mg/L resolution, even though both are technically equally accurate. In aquaculture monitoring, this ability to track trends is especially useful because it lets fish keep breathing by correcting DO levels before they drop too low and cause stress or death.


Temperature Compensation: Why Automatic Correction Is Essential for Accurate DO Readings


The amount of dissolved oxygen depends on temperature; cold water holds much more oxygen than warm water at the same atmospheric pressure. This means that a raw DO electrode signal changes with water temperature, even if the oxygen level doesn't.


Automatic Temperature Compensation (ATC) uses a temperature sensor built into the probe to continuously measure water temperature and apply a corrective factor to the DO reading in real time. This gives accurate mg/L and percentage saturation values even if the temperature changes during sampling.


Salinity and Altitude Correction: Extending Measurement Accuracy Across Diverse Water Environments


A standard dissolved oxygen measurement assumes that the water is fresh and at sea level pressure. These are two situations that are completely unique in the real world, where DO meters are used. Coastal aquaculture, estuary tracking, marine aquarium management, and seawater treatment systems all need to adjust their water salinity because dissolved salts reduce their ability to carry oxygen at the same temperature as freshwater.


Altitude correction accounts for the lower atmospheric pressure at higher elevations, which, in turn, lowers the partial pressure of oxygen and, as a result, the dissolved oxygen equilibrium percentage in surface water. For field researchers and aquaculture workers working at elevations above 500 meters, a portable DO meter that can correct for altitude is a useful feature, not an extra.


Choosing a Dissolved Oxygen Meter by Water Environment


Different water settings stress a meter in different ways; this table pairs each environment with the capability that matters most and what to watch for before you buy.


Water Environment DO Behaviour to Expect Correction to Enable What to Watch For
Freshwater aquaculture (ponds, tanks) Usually 6 to 12 mg/L, dropping overnight Automatic temperature compensation Low pre-dawn oxygen stresses fish; track trends, not single reads
Coastal or marine aquaculture Lower capacity as dissolved salts cut oxygen Salinity correction Without salinity set, the meter overreads brackish and sea water
River and stream field sampling Near zero at depth to supersaturated at surface Wide range plus temperature compensation One site can span the full scale; confirm range headroom first
Wastewater and aeration control Driven by blowers, read as percent saturation Percent-saturation mode Use saturation to judge aeration efficiency, mg/L for discharge limits
High-altitude sites (above 500 m) Lower equilibrium as air pressure falls Altitude or pressure correction Skipping altitude correction inflates the saturation reading noticeably

How Display Features & Calibration Define the Daily Usability of Your Dissolved Oxygen Meter


In addition to how well it measures, a dissolved oxygen meter's display and calibration system determine how useful it is in everyday lab and field use. A device that is hard to read in bright outdoor conditions or takes a long time to stabilize during calibration adds extra work to every measurement session, which defeats the purpose of portable, on-site testing to save time.


Display Technology and Readability: Choosing a DO Meter That Works in Every Lighting Environment


Display quality really matters for how easy it is to read measurements, whether in full sunlight, a lab with low light, or the field while wearing gloves. Backlit LCDs are the standard format for most portable dissolved oxygen meters. They make it easy to read the numbers indoors and in low light, and they use less battery power than display technologies with better specifications.


High-contrast backlit screens with brightness settings work well to get around this problem because they keep the text clear from direct sunlight to total darkness without the operator having to shade the instrument or move in relation to the light source. Large-digit primary displays that clearly show the DO reading, along with secondary parameters like temperature, percentage saturation, and battery status, are best for professional field use.


Calibration Methods and Maintenance: Keeping Your Dissolved Oxygen Meter Accurate Over Time


Calibration is the process that ensures a dissolved oxygen meter continues to give accurate readings throughout its use. How often and how easily the instrument is calibrated in practice depends on how straightforward and reliable the calibration procedure is, which is just as important as the instrument's initial factory-issued accuracy specification. There are two main ways to calibrate most reliable DO meters: air-saturated water calibration and water-saturated air calibration. In air-saturated water calibration, the probe is submerged in vigorously aerated water until it is atmospherically saturated. In water-saturated air calibration, the probe membrane is exposed to air at 100% relative humidity in a closed calibration chamber.


Many field and aquaculture applications use single-point calibration at atmospheric saturation. This process is standard and takes less than 2 minutes on well-designed portable DO meters with automatic calibration recognition, which locks in the calibration value once the probe signal has stabilized. For study and compliance purposes that need accurate measurements across the whole measurement range, two-point calibration is typically required. This involves adding a zero-point reference using an oxygen-free sodium sulfite solution.


VEVOR Dissolved Oxygen Meter 9011B: Key Capabilities


The VEVOR Dissolved Oxygen Meter 9011B, 0.0-50.0 mg/L, the one model currently listed in this category, breaks down by capability below. All values are taken from its VEVOR product page.


Capability Verified Specification Function Where It Helps Buyer Takeaway
Measurement range 0.00 to 50.00 mg/L DO; 0.0 to 500.0% air saturation Reads anoxic to supersaturated water on one scale River sampling, aeration checks, aquaculture Wide headroom covers surface and deep readings on one meter
Accuracy and ATC Accuracy ±2% of reading; automatic temperature compensation Corrects the reading as water temperature shifts Field sampling where temperature varies Readings stay honest without manual recalculation between samples
Salinity and pressure correction Salinity 0.0 to 40.0 g/L; pressure 600 to 1100 hPa, adjustable Adjusts for dissolved salts and altitude Coastal, marine, and high-elevation sites One meter reads fresh, brackish, and saline water accurately
Data and connectivity 750 data sets; Bluetooth and USB transfer Logs on board and exports to phone or PC Compliance logging and multi-site monitoring Cuts manual note-taking and keeps an auditable record
Durability and display IP67 housing; 13.1 ft stainless electrode; backlit LCD Survives damp field use and reads in sunlight Outdoor ponds, tanks, and wastewater work Built for the field; the long cable reaches deep tanks

Why Choose VEVOR Dissolved Oxygen Meters for Your Water Quality Testing?


VEVOR's dissolved oxygen meters give accurate, temperature-adjusted readings in aquaculture, the environment, the lab, and wastewater. They come in portable, field-ready, and benchtop styles to fit any tracking situation. Every device, from small, portable DO meters for sampling on-site to high-resolution dissolved oxygen testers for analytical work, combines accurate measurement with ease of use. VEVOR's full line of DO meters is available at low prices and comes with reliable customer service after the sale. Look through them today to get accurate tracking of water quality in any setting where you work.


FAQs


How often should I calibrate my dissolved oxygen meter?


Calibrate your dissolved oxygen tester before each measurement session for critical applications, or at a minimum once daily during regular monitoring use. Membrane condition, temperature changes, and probe age all affect reading accuracy over time. Regular calibration ensures readings remain within the instrument's stated accuracy specification throughout its operational life.


What is the difference between mg/L and percentage saturation readings on a DO meter?


mg/L measures the absolute mass of dissolved oxygen per liter of water. Percentage saturation expresses the DO level relative to the maximum the water can hold at the current temperature and pressure. Both parameters are useful: mg/L for biological thresholds and percentage saturation for aeration system efficiency assessment.


Can portable dissolved oxygen meters be used in saltwater environments?


Yes, provided the model includes the capability to correct for salinity. Standard portable DO meters without salinity compensation will overread in marine and brackish water. VEVOR's dissolved oxygen meters with salinity correction deliver accurate readings across freshwater, brackish, and full marine salinity ranges when the correct salinity value is entered before measurement.


How do I know when the probe membrane needs to be replaced on my DO meter?


Replace the membrane when readings become slow to stabilize, drift inconsistently, or calibration cannot be achieved within the instrument's normal acceptance window. Most dissolved oxygen tester manufacturers recommend replacing the membrane every 1–3 months under regular use, or immediately if physical damage to the membrane surface is visible.


What dissolved oxygen level indicates healthy water for fish farming?


Most freshwater fish species require a minimum of 5–6 mg/L for healthy growth, with optimum levels between 7 and 9 mg/L for intensive aquaculture systems. A reliable portable DO meter with continuous monitoring capability helps aquaculture operators detect declining oxygen levels before they approach critical thresholds associated with fish stress or mortality.


Can you recommend portable dissolved oxygen meters for field use?


For field work, choose a portable dissolved oxygen meter with a long electrode cable, automatic temperature compensation, and a waterproof, backlit housing you can read in sunlight. VEVOR's portable tester kit offers a 13.1 ft cable, on-board data storage, and Bluetooth transfer, which suits pond, river, and aquaculture sampling.


How do I choose the right dissolved oxygen meter for my water quality testing?


Start with your water: match the measurement range to expected oxygen levels, then confirm the accuracy and resolution your decisions need. Add salinity and altitude correction for coastal or high-elevation sites, and pick a form factor, portable or benchtop, that fits where you test. Browse VEVOR's dissolved oxygen meters to compare options.


What is the difference between a dissolved oxygen meter and a dissolved oxygen sensor?


The sensor, or probe, is the part that touches the water and turns the oxygen present into a raw electrical or optical signal. The meter is the handheld or benchtop unit that powers the sensor, applies temperature and calibration corrections, and shows the result in mg/L or percentage saturation. Together they form one measuring system.


Tips & Inspiration